Combined Cycle Power Plant

By |

The following interactive 3D model shows a combined cycle power plant (CCPP) with its turbines opened up: the upper casing halves lie beside the machines as during an overhaul, exposing rotors, blades and combustion chamber. Click on a component or a pipe to have it explained.

Embed this animation in your website or learning platform

Copy the code and paste it into your website or learning platform (e.g. Moodle, ILIAS – in HTML mode). The animation stays up to date automatically, and the link leads back to this page.

<div style="position:relative;width:100%;aspect-ratio:16/9"><iframe src="https://www.educational-animation.org/web-animations/gas-fired-power-plant/en/gas-fired-power-plant.html" title="Interactive animation: Combined Cycle Power Plant" style="position:absolute;inset:0;width:100%;height:100%;border:0" allowfullscreen loading="lazy"></iframe></div>
<p><a href="https://www.educational-animation.org/en/combined-cycle-power-plant/">Combined Cycle Power Plant – educational-animation.org</a> · MIT licence</p>

Links

Have you fixed a bug in the animation or made an improvement? Send us your animation via our contact form.

Description

The 3D model depicts a modern combined cycle power plant in which a gas turbine and a steam turbine are combined. Both turbines are open: you can see the drum rotor of the gas turbine with 13 compressor and 4 turbine stages, the stator blades in the casing and the annular combustion chamber with its burners; on the steam turbine the high-, intermediate- and double-flow low-pressure sections. All pipes run the way they work: main steam, reheat, crossover pipe, feedwater and cooling water circuits. The model can be freely rotated, zoomed and panned.

Clicking on a component or a pipe displays an explanation. This makes it possible to follow the path of energy: from the natural gas via the hot exhaust gas and the steam to the electricity from two generators.

Components of the Combined Cycle Power Plant

The table shows the components and their function.

ComponentDescription
Air filter and intakeFine filters keep dust and pollen away from the compressor blades; the duct carries the air into the intake casing.
Natural gas supplyPressure-regulating station (around 30 bar) and ring main around the combustion chamber distributing the gas to the 16 burners.
Compressor13 rotor rows with stator rows in the casing between them. Compresses the air to around 20 bar; it reaches about 400 °C in the process.
Annular combustion chamberAnnular space around the shaft with inner flame tube and 16 burners. Natural gas burns with the compressed air at around 1400 °C.
TurbineFour rotor rows, each preceded by a stator row; the blades get longer towards the back. The exhaust gas leaves at around 600 °C.
Gas turbine rotorA single drum rotor carries the compressor and turbine blades; about two thirds of the turbine work is used by the compressor itself.
GeneratorsOne generator each on the gas and steam turbine; 3000 rpm give 50 Hz. During start-up the gas turbine generator briefly works as a motor.
Step-up transformersRaise the generator voltage from around 20 kV to 380 kV for the transmission grid.
Heat recovery steam generatorA boiler without a flame: the exhaust gas passes economiser, evaporator with drum and superheater and cools to around 90 °C. Downcomers return water from the drum to the evaporator.
StackDischarges the cooled exhaust gas.
Main steam lineFrom the superheater at the hot end of the boiler to the high-pressure section of the steam turbine (560 °C, around 130 bar).
ReheatCold reheat line from the high-pressure section back into the boiler, hot reheat line from the reheater to the intermediate-pressure section.
Steam turbineHigh-, intermediate- and double-flow low-pressure sections with rotor and stator rows; the exhaust steam goes down into the condenser.
Crossover pipeCarries the steam from the intermediate-pressure section into the middle of the low-pressure section, where it splits to both sides.
CondenserCondenses the exhaust steam at around 0.05 bar on tubes carrying cooling water.
Feedwater circuitCondensate pump, feedwater tank with deaerator and feedwater pump (over 100 bar) return the water to the economiser.
Cooling water circuitCooling water pump with supply and return lines between condenser and cooling tower.
Cooling towerReleases the condenser heat – around a third of the fuel energy – into the air.

Interactive Controls

The 3D model can be controlled with the following inputs:

  • Rotate: Hold down the left mouse button and drag
  • Zoom: Turn the mouse wheel or use a two-finger gesture on the touchscreen
  • Pan: Hold down the right mouse button and drag
  • Select object: Click on a component or a pipe to display its description

Technical Background

A combined cycle power plant links two thermodynamic cycles. The gas turbine operates on the Brayton cycle (also known as the Joule cycle): air is compressed, burned with natural gas at very high temperatures and then expanded in the turbine. However, the exhaust gas still leaves the gas turbine at around 600 °C and therefore contains a large share of the energy input.

This waste heat is used in the heat recovery steam generator to evaporate and superheat water. In the Rankine cycle, the steam drives a steam turbine, is condensed back into water in the condenser and returned as feedwater. By coupling both cycles, combined cycle power plants achieve electrical efficiencies of around 60 %, making them among the most efficient fossil-fuelled power plants.

Another advantage is their high flexibility: gas turbines can be started up and shut down comparatively quickly. Combined cycle power plants are therefore well suited to balancing fluctuations in the feed-in of renewable energy.

Physical Background

On its own, the gas turbine manages just under 40 %. From its waste heat, the steam turbine extracts roughly another third. Together, that comes to around 60 % – a short calculation shows how it adds up.

Why Together They Reach Around 60 %

The overall efficiency of a combined cycle power plant can be approximated from the efficiencies of the two sub-processes:

\[ \eta_{CC} = \eta_{GT} + (1-\eta_{GT}) \cdot \eta_{ST} \]

  • \( \eta_{CC} \) – overall efficiency of the combined cycle power plant
  • \( \eta_{GT} \) – efficiency of the gas turbine (approx. 38–42 %)
  • \( \eta_{ST} \) – efficiency of the steam cycle relative to the gas turbine’s waste heat (approx. 30–35 %)

Example: with \( \eta_{GT} = 0.38 \) and \( \eta_{ST} = 0.35 \), the result is \( \eta_{CC} = 0.38 + 0.62 \cdot 0.35 \approx 0.60 \). The steam turbine thus uses part of the energy that would otherwise escape unused through the stack in a simple cycle gas turbine plant. The upper limit for any heat engine is the Carnot efficiency, which depends on the highest and lowest process temperatures.

Notes on the Model

The 3D model is deliberately simplified: buildings, boiler and cooling tower are schematic bodies, the blades are inclined flat plates rather than twisted aerofoils, and the combustion chamber is an annular type – other manufacturers use individual can combustors. A real combined cycle power plant comprises many further components, such as bypass stations, lubricating oil systems, exhaust gas treatment (SCR catalyst), water treatment, instrumentation and control, and extensive safety equipment. Layout and proportions may vary considerably from plant to plant; the figures quoted (20 bar, 1400 °C, 600 °C, 560 °C at 130 bar, 270 + 160 MW) are typical guide values for a large plant.

Use in the Classroom

Tasks

Tasks that can be worked through with the animation:

  1. Click in turn on the air filter, compressor, annular combustion chamber, turbine, heat recovery steam generator, main steam line, steam turbine and one generator. Describe in five sentences how the energy travels from the natural gas to the electricity.
  2. Click on “Turbine” and “Heat recovery steam generator”. At what temperature does the exhaust gas leave the gas turbine, and at what temperature does it leave the boiler? Why would it be wasteful to send it straight up the stack?
  3. Find the generators in the model. How many are there, and which machine drives which?
  4. Click on “Condenser”, “Cooling water circuit” and “Stack”. Where does heat leave the plant without producing electricity?
Worksheets

Worksheet “Efficiency of a Combined Cycle Power Plant” with answers: Word (editable) · PDF

Related Animations

Overview

TitleCombined Cycle Power Plant
Target groupTeachers and presenters
Features3D model with opened-up turbines
Explanations by clicking on components and pipes
Full screen mode
Lossless scaling
Supports large screens and projection screens
LicenceAnimation (code): MIT · Text and graphics: CC BY 4.0

Sources and Origin

  • R. Kehlhofer, F. Hannemann, F. Stirnimann, B. Rukes: Combined-Cycle Gas & Steam Turbine Power Plants. PennWell, Tulsa.
  • H. I. H. Saravanamuttoo, G. F. C. Rogers, H. Cohen, P. V. Straznicky, A. C. Nix: Gas Turbine Theory. Pearson, Harlow.
  • C. Lechner, J. Seume (eds.): Stationäre Gasturbinen. Springer Vieweg, Berlin.

The 3D models and parts of the program code for this animation were created with the help of AI tools. The idea, design and technical responsibility remain with us.

Cite this post

The animation (code) is published under the MIT licence, text and graphics under CC BY 4.0: you may use, share and modify everything freely – please give credit. The easiest way is to copy this citation:

Sebastian Rikowski: Combined Cycle Power Plant. educational-animation.org, 2026. https://www.educational-animation.org/en/combined-cycle-power-plant/ – Licence: code MIT, text and graphics CC BY 4.0.

If you use the animation, we would greatly appreciate a link to our site or a brief mention of it. It helps others find us – and helps us keep going.