The animation shows a three-phase squirrel-cage induction motor in cross-section. You can see the currents in the stator slots, the rotating magnetic field, the induced currents in the rotor bars and the rotor field they produce. A characteristic diagram shows torque and current versus speed. Load torque, type of driven machine and supply frequency are adjustable; the speed settles by itself.
Embed this animation in your website or learning platform
Copy the code and paste it into your website or learning platform (e.g. Moodle, ILIAS – in HTML mode). The animation stays up to date automatically, and the link leads back to this page.
<div style="position:relative;width:100%;aspect-ratio:16/9"><iframe src="https://www.educational-animation.org/web-animations/induction-motor/en/induction-motor.html" title="Interactive animation of an asynchronous motor" style="position:absolute;inset:0;width:100%;height:100%;border:0" allowfullscreen loading="lazy"></iframe></div>
<p><a href="https://www.educational-animation.org/en/interactive-animation-of-an-asynchronous-motor/">Interactive animation of an asynchronous motor – educational-animation.org</a> · MIT licence</p>
Links
Have you fixed a bug in the animation or made an improvement? Send us your animation via our contact form.
Description of the Animation
The animation is divided into two areas that show the same operating state from two perspectives: on the left the inside of the machine, on the right its behaviour as a characteristic curve. When a slider is changed, both react simultaneously.
Left: the motor cross-section
The motor shown is a two-pole machine. The stator has 18 slots containing the windings of the three phases U, V and W (brown, black, grey). Each phase occupies three adjacent slots per pole; the zone sequence is U+ W− V+ U− W+ V−. In each slot the conductor cross-section is marked with a current symbol: ⊗ means current into the page, ⊙ current out of the page. The opacity of the symbol is proportional to the instantaneous value of the current. Next to the motor, a bar display shows the three phase currents, each shifted by 120° relative to the others.
The purple field lines show the stator field. They run straight across the rotor and close via the stator yoke. The pole marks N and S on the outer edge make visible how the field rotates, even though nothing moves in the stator – only the currents change.
The rotor carries 12 bars that are connected to each other at both ends by short-circuit rings (squirrel cage). Here, too, current symbols show the direction and strength of the induced currents. A key on the shaft makes the rotation of the rotor easy to see. Optionally, the teal rotor field produced by the bar currents can be displayed. Its opacity increases with the rotor current: at standstill it is strong, close to synchronous speed it fades almost completely.
The air gap between stator and rotor is greatly enlarged for better visibility; in real machines it is only a fraction of a millimetre. The motion runs in slow motion (factor 1/400). At 50 Hz, the rotating field therefore takes 8 seconds for one revolution. All numerical values displayed, however, are real values.
Right: the characteristic diagram
Three curves are plotted against the speed \( n \): the torque-speed characteristic of the motor (blue), the load characteristic of the driven machine (orange) and the stator current \( I_1 \) (red, separate scale on the left). Marked are the starting torque \( T_{st} \), the breakdown torque \( T_{max} \) and the synchronous speed \( n_s \) as a dashed line.
The red dot shows the current operating point on the motor characteristic; below it are the corresponding points on the load and current curves. As long as motor torque and load torque differ, a green arrow connects the two curves: it represents the accelerating torque. If it points upward, the rotor speeds up; if it points downward, the rotor slows down. When it disappears, steady-state operation has been reached.
Status line and measured values
At the top left, a status line reports the operating state: Rotor accelerating, Steady-state operation, Rotor decelerating, Overload: motor stalls or Rotor locked. The measured values are shown at the bottom right: synchronous speed, rotor speed, slip, motor torque, load torque as well as line voltage and stator current.
Interactive Controls
- Driven machine (drop-down list): Determines how the load torque depends on speed – hoist, fan/pump, agitator/mixer or conveyor.
- Load torque \( T_L \) (0–120 Nm): The counter-torque of the driven machine. For the fan and the agitator, the slider sets the load torque at 3000 rpm; for the conveyor, it sets the running torque.
- Supply frequency \( f \) (10–50 Hz): Simulates a variable-frequency drive. The voltage is adjusted proportionally (V/f = constant).
- Checkboxes: Show or hide the stator field, the rotor field and the current symbols. The rotor field is hidden at startup.
- Pause/Play: Stops the animation so that a snapshot can be examined at leisure.
The speed itself cannot be set directly. It results from motor torque, load torque, friction and the inertia of motor and driven machine – just as in a real machine. At startup, the motor accelerates from standstill against a load torque of 25 Nm.
Observation tip
It is best to start by looking at the stator slots and the bar display: wherever a phase is currently carrying its largest current, the symbols are strongest. This spot moves from slot to slot – and with it the pole marks of the stator field. Next, it is worth comparing the key on the shaft with a pole mark: in steady-state operation, the rotor slowly falls behind the field. Finally, display the rotor field and change the load – the greater the load, the stronger the teal field becomes.
How an Induction Motor Works
As its name says, the induction motor works by induction alone. The rotor has no electrical connection, no slip rings and no brushes. It receives its currents exclusively through electromagnetic induction from the stator field – much like the secondary winding of a transformer. This makes it robust, low-maintenance and inexpensive.
The chain of effects runs in four steps:
- Three-phase current → rotating field: Three windings displaced in space by 120° carry three currents displaced in time by 120°. Together they produce a magnetic field of constant strength that rotates uniformly.
- Rotating field → induction: As long as the rotor is slower than the field, the field lines cut the rotor bars. A voltage is induced in the bars.
- Induction → rotor current: Because the bars are connected by the short-circuit rings, a large current flows. It produces its own magnetic field, the rotor field.
- Current in the field → torque: The Lorentz force acts on the current-carrying bars in the stator field. Put simply, the stator field drags the rotor field along behind it – the rotor turns in the direction of the rotating field.
The alternative name asynchronous motor describes the decisive property: the rotor can never quite catch up with the rotating field. If it ran exactly in synchronism, the field lines would no longer cut the bars, no voltage would be induced, no current would flow and no torque would be produced. The motor needs the speed difference in order to produce torque at all.
Physical Background
The rotating field goes round, the rotor follows – and it is exactly this lag, the slip, that produces torque. The sections below explain how rotating field, slip, torque and speed are related.
Rotating Field and Synchronous Speed
The rotating field turns at the synchronous speed. It depends only on the supply frequency \( f \) and the number of pole pairs \( p \):
\[ n_s = \frac{60 \cdot f}{p} \]
The motor in the animation is a two-pole machine (\( p = 1 \)). At 50 Hz this gives \( n_s = 3000 \) rpm. A four-pole motor would reach 1500 rpm, a six-pole motor 1000 rpm. More poles therefore mean a lower speed – without a gearbox.
In the animation, the formation of the rotating field can be followed directly: the stator winding stands still, yet the pole marks N and S move uniformly around the stator. If the frequency is lowered, currents and field run more slowly, and the dashed line \( n_s \) in the diagram moves to the left.
Slip
The relative speed difference between the rotating field and the rotor is called slip:
\[ s = \frac{n_s-n}{n_s} \]
At standstill \( s = 1 \) (100 %), at synchronous speed \( s = 0 \). At rated operation, the slip of the motor in the animation is about 3 %, so the speed is around 2910 rpm. The rotor then falls behind by just over 10° per revolution of the rotating field. This is easy to observe in the animation by comparing the key on the shaft with a pole mark.
From the rotor’s point of view, the field rotates only at the difference speed. The rotor currents therefore do not have the supply frequency but the much lower rotor frequency:
\[ f_2 = s \cdot f \]
At 3 % slip and 50 Hz, that is only 1.5 Hz. In the animation this can be seen in the rotor bars: shortly after switching on, the current symbols in the rotor change just as quickly as in the stator; during operation close to synchronous speed, they change only very slowly in any one bar. The current pattern then moves almost rigidly along with the field.
The Torque-Speed Characteristic
The animation calculates the torque from the single-phase equivalent circuit of the machine. If the supply, stator resistance and stator reactances are combined into an equivalent source \( U_{th} \) with internal resistance \( R_{th} \) and reactance \( X_{th} \) (Thevenin equivalent), the torque is:
\[ T = \frac{3}{\omega_s} \cdot \frac{U_{th}^2 \; R_2^{\prime}/s}{\left( R_{th} + R_2^{\prime}/s \right)^2 + \left( X_{th} + X_2^{\prime} \right)^2} \]
- \( \omega_s \) – angular velocity of the rotating field
- \( R_2^{\prime} \), \( X_2^{\prime} \) – resistance and leakage reactance of the rotor, referred to the stator
- \( s \) – slip
The curve has a characteristic shape that can be divided into three sections:
- Starting (\( n = 0 \)): The motor develops the starting torque \( T_{st} \approx 78 \) Nm. The rotor current is very large but not very effective, because at high rotor frequency the rotor is predominantly inductive.
- Breakdown point: At about 2400 rpm the torque reaches its maximum, the breakdown torque \( T_{max} \approx 110 \) Nm.
- Operating range (between the breakdown point and \( n_s \)): The torque drops steeply and almost linearly to zero. This is where the motor works in normal operation.
For a quick estimate, the simplified Kloss formula is often used, which requires only the breakdown torque and the breakdown slip \( s_b \):
\[ \frac{T}{T_{max}} = \frac{2}{\frac{s}{s_b} + \frac{s_b}{s}} \]
At small slip (\( s \ll s_b \)), the second term \( s_b/s \) in the denominator dominates, so the torque is approximately proportional to the slip: \( T \approx 2\,T_{max} \cdot s/s_b \). Example: with \( s_b = 0.2 \) and \( s = 0.03 \), the formula gives \( 0.293\,T_{max} \), the approximation \( 0.30\,T_{max} \). This is why the characteristic is almost linear in the operating range: twice the load means roughly twice the slip.
Stator field and rotor field
With the rotor field displayed, the shape of the characteristic can also be understood intuitively. The rotor field lags the stator field by \( 90° + \varphi_2 \), where \( \varphi_2 \) is the phase angle of the rotor circuit:
\[ \tan \varphi_2 = \frac{s \, X_2^{\prime}}{R_2^{\prime}} \]
In the operating range the slip is small, \( \varphi_2 \) is almost zero, and the two fields are almost exactly perpendicular to each other. This is the most favourable position: every ampere of rotor current contributes fully to the torque. At standstill, on the other hand, \( \varphi_2 \) is large (about 50° in the animation), and the fields point more against each other than across. Despite the very large current, only a moderate torque is produced. In the animation, you can see during run-up how the teal rotor field turns relative to the purple stator field and fades at the same time.
Skin effect
At standstill, the rotor currents have the full supply frequency. The current in the bar is then pushed outwards towards the air gap, the effective cross-section becomes smaller and the resistance larger. The animation models this effect in simplified form:
\[ R_2^{\prime}(f_2) = R_{2,0}^{\prime} \left( 1 + \left( \frac{f_2}{f_N} \right)^2 \right) \]
When starting at 50 Hz, the rotor resistance doubles; during operation at low rotor frequency the effect is negligible. This is a welcome side effect: without the skin effect, the starting torque of this motor would be only about 45 Nm instead of 78 Nm. Manufacturers deliberately enhance the effect with tall, narrow bars (deep-bar rotor) or two cages on top of each other (double-cage rotor).
The Starting Current
The red current curve shows one of the most important properties of the induction motor: when switched directly onto the supply, it draws a multiple of its rated current. At standstill, the motor behaves like a transformer with a short-circuited secondary; only the winding resistances and leakage reactances limit the current. The motor in the animation draws around 110 A when starting, about 5.4 times its rated current of around 20 A.
The current remains almost constantly high until shortly before the breakdown point and only drops steeply in the operating range. Even at no load it does not drop to zero: what remains is the magnetising current that the motor needs to build up the rotating field. With large motors, the starting current places a considerable load on the supply. They are therefore started via star-delta connection, soft starters or variable-frequency drives.
How the Speed Settles
The animation integrates the rotational motion from the torque balance. The rotor is driven by the motor torque and braked by the load torque of the driven machine and by friction:
\[ J \frac{\mathrm{d}\omega}{\mathrm{d}t} = T-T_L-T_{\text{friction}} \]
The right-hand side is exactly the accelerating torque that appears as a green arrow in the diagram. With the small moment of inertia of the model, run-up against 25 Nm takes only about 0.16 s. With heavy driven machines it often takes several seconds in practice. In slow motion the run-up can be followed comfortably. Equilibrium is reached where the motor and load characteristics intersect.
Stable operation and stalling
To the right of the breakdown point, operation is inherently stable: if a load disturbance slows the motor down slightly, its torque rises and accelerates it again. To the left of the breakdown point it is the other way round – if the motor slows down there, its torque drops and it becomes even slower. If the load torque exceeds the breakdown torque, the speed therefore collapses abruptly. The motor stalls.
This can be tried out well with the “Hoist” load. If 90 Nm is set at standstill, the motor cannot start because the load torque is above the starting torque (Rotor locked). If, on the other hand, the motor is already running and the load is slowly increased to 90 Nm, it carries it without any problem. Only above about 110 Nm does it stall. Whether a motor can handle a load therefore depends not only on the load itself, but also on how it got there.
Driven Machines and Their Load Characteristics
Every driven machine has its own load characteristic. The animation offers four typical cases:
| Hoist | Constant torque, independent of speed. The full load must already be lifted at standstill, so the starting torque is critical. |
| Fan, pump | Torque increases with the square of the speed (\( T_L \sim n^2 \)). At standstill the load is almost zero, so starting is easy. Typical of turbomachines. |
| Agitator, mixer | Torque increases linearly with speed (\( T_L \sim n \)), for example due to fluid friction in viscous media. |
| Conveyor | At standstill, an additional breakaway torque must be overcome (80 % above the running torque), which decays quickly once the belt is moving. |
The conveyor shows a case from practice: from a running torque of about 43 Nm upwards, the breakaway torque exceeds the starting torque of the motor. The belt stays still, even though the motor could easily carry the load while running. With fans and pumps this problem never occurs, because the load only rises with speed.
Power and Rotor Losses
The power transferred across the air gap, \( P_\delta = T \cdot \omega_s \), is split in the rotor into two parts: the mechanical output power and the heat losses in the rotor bars.
\[ P_{\text{mech}} = (1-s) \, P_\delta \qquad P_{\text{Cu2}} = s \, P_\delta \]
The slip is therefore a direct measure of the losses in the rotor. At 3 % slip, 3 % of the air-gap power is lost as heat. At standstill, by contrast, the entire air-gap power is dissipated in the rotor – which is why a locked motor may only remain switched on for a short time, and why an induction motor should always be operated at low slip.
The output power follows from torque and speed:
\[ P = T \cdot \omega = T \cdot \frac{2 \pi n}{60} \]
With the rated torque of about 36 Nm at 2910 rpm, this gives around 11 kW, the rated power of the motor in the animation.
Speed Control with a Variable-Frequency Drive
On a fixed supply, an induction motor always runs just below synchronous speed. To change the speed, the frequency must be changed. This is done by a variable-frequency drive (frequency converter). So that the magnetic field keeps its strength, the voltage is changed in the same ratio as the frequency:
\[ \frac{U}{f} = \text{constant} \]
The reason: the reactances of the winding increase in proportion to the frequency. If the full voltage were applied at low frequency, an excessive magnetising current would flow and the iron would saturate. At very low frequencies, the voltage is raised slightly (boost) to compensate for the voltage drop across the stator resistance. The measured values show the line voltage currently applied.
In the diagram, the entire characteristic shifts to the left together with the synchronous speed, but its shape in the operating range remains similar: the speed changes, the stiffness of the drive is preserved. At low frequencies the stator resistance becomes noticeable: the breakdown torque drops (to around 80 Nm at 10 Hz), and the breakdown point moves closer to standstill. At the same time, the starting current falls considerably, while the starting torque stays about the same. Starting at low frequency is therefore particularly gentle on the supply.
Design Data of the Animation
| Rated power | 11 kW |
| Rated voltage | 400 V, star connection |
| Rated frequency | 50 Hz |
| Number of pole pairs \( p \) | 1 (two-pole) |
| Synchronous speed \( n_s \) | 3000 rpm |
| Rated speed | around 2910 rpm |
| Rated torque \( T_N \) | around 36 Nm |
| Starting torque \( T_{st} \) | around 78 Nm |
| Breakdown torque \( T_{max} \) | around 110 Nm at about 2400 rpm |
| Starting current | around 5.4 times rated current |
| Stator | 18 slots, single-layer winding, 3 slots per pole and phase |
| Rotor | squirrel cage with 12 bars |
| Moment of inertia \( J \) | 0.02 kg m² (motor and driven machine) |
| Supply frequency \( f \) | 10–50 Hz (V/f = constant) |
| Load torque | 0–120 Nm |
| Slow motion | 1 : 400 |
Simplifications of the Animation
- Steady-state model: The torque is calculated from the steady-state equivalent circuit. Electrical transients when switching on, which in reality cause brief torque surges, are not included.
- Field pattern: Stator field and rotor field are drawn separately. In the real machine they superimpose to form a single resultant air-gap field.
- Geometry: The air gap and conductor cross-sections are exaggerated. Real rotor bars are skewed to reduce noise and torque pulsations.
- Losses: Iron losses and saturation are not taken into account; the skin effect is modelled only in simplified form.
Induction Motors in Practice
- Industry: The squirrel-cage motor is the most widely built electric motor of all. It drives pumps, fans, compressors, conveyor systems and machine tools. Electric drives consume around two thirds of the electricity used in industry, most of it in induction motors.
- Energy efficiency: Motors are divided into efficiency classes (IE1 to IE5). For pumps and fans, a variable-frequency drive often saves more energy than a better motor, because the power falls with the cube of the speed.
- Starting methods: Small motors are switched on directly. Larger motors are started via star-delta connection, soft starters or variable-frequency drives to limit the starting current.
- Vehicles: Locomotives, trams and some electric cars use inverter-fed induction motors. They are robust, need no rare-earth magnets and produce no drag losses from magnetic fields when coasting.
- Household: Washing machines, refrigerator compressors and circulation pumps often contain induction motors; on single-phase supplies, usually with a capacitor as an auxiliary phase.
Historical Background
The basis of the induction motor is the rotating magnetic field. In 1885 in Turin, Galileo Ferraris showed that two phase-shifted alternating currents in offset coils produce a rotating magnetic field that drags a metal cylinder along with it. Independently of this, Nikola Tesla developed polyphase motors and filed patents for them in the USA in 1887/1888.
The breakthrough came from Mikhail Dolivo-Dobrovolsky, who developed the squirrel-cage rotor and the three-phase system at AEG in Berlin in 1889; he called it “Drehstrom” (rotary current). In 1891, at the International Electrotechnical Exhibition in Frankfurt am Main, three-phase power was transmitted for the first time over a distance of 175 km from Lauffen am Neckar. With this, three-phase current prevailed over direct current as the basis of power supply – and with it the induction motor as the standard drive. The basic principle has not changed since.
Use in the Classroom
Tasks
Tasks that can be worked through with the animation:
- Using the initial values (hoist, 25 Nm, 50 Hz), watch the motor run up to steady operation. Read off the synchronous speed ns, the rotor speed n and the slip s. Compare how fast the current symbols in the rotor bars change shortly after starting and in operation.
- Raise the load torque TL in steps of 25 Nm up to 100 Nm and note n, s and I1 each time. How does the slip depend on the load? At which load torque does the motor stall?
- Let the motor stall with TL = 115 Nm until it stands still. Then lower the load torque to 80 Nm: does the motor start again? Find the largest load torque at which it starts from standstill and compare it with the starting torque Tst in the diagram.
- Set TL = 36 Nm and lower the supply frequency from 50 Hz to 25 Hz. Compare ns, n and the difference ns − n. Also switch on the rotor field: how are the stator field and the rotor field positioned relative to each other in operation?
Worksheets
Worksheet “Rotating Field, Slip and Characteristic of an Induction Motor” with answers: Word (editable) · PDF
Graphics
Graphics from the animation as SVG – they scale without loss for worksheets, slides or the board. Click to open a graphic; right-click → “Save as …” to download it.
Torque and current characteristics at 50 Hz, hoist with 36 Nm: steady operating point
Characteristics at 25 Hz (constant V/f), hoist with 36 Nm
Cross-section in operation (50 Hz, 36 Nm): stator field (violet) and rotor field (teal), phase currents
Licence for graphics and worksheets: CC BY 4.0 – please credit “educational-animation.org”.
Related Animations
Further Resources
- Induction motor – Wikipedia – construction, equivalent circuit and operating behaviour
- Rotating magnetic field – Wikipedia – how a rotating field is produced from three-phase current
- Variable-frequency drive – Wikipedia – speed control of three-phase motors
Overview
| Title | Interactive animation of an asynchronous motor |
| Target audience | Teachers and presenters |
| Features | Full-screen mode Lossless zoom Supports large screens and projectors |
| Licence | Animation (code): MIT · Text and graphics: CC BY 4.0 |
Sources and Origin
- R. Fischer: Elektrische Maschinen. Carl Hanser Verlag, Munich.
- A. Binder: Elektrische Maschinen und Antriebe. Springer Vieweg, Berlin.
- G. Müller, B. Ponick: Grundlagen elektrischer Maschinen. Wiley-VCH, Weinheim.
- S. J. Chapman: Electric Machinery Fundamentals. McGraw-Hill, New York.
Parts of the program code for this animation were created with the help of AI tools. The idea, design and technical responsibility remain with us.
Cite this post
The animation (code) is published under the MIT licence, text and graphics under CC BY 4.0: you may use, share and modify everything freely – please give credit. The easiest way is to copy this citation:
Sebastian Rikowski: Interactive animation of an asynchronous motor. educational-animation.org, 2026. https://www.educational-animation.org/en/interactive-animation-of-an-asynchronous-motor/ – Licence: code MIT, text and graphics CC BY 4.0.
If you use the animation, we would greatly appreciate a link to our site or a brief mention of it. It helps others find us – and helps us keep going.