The following interactive 3D model shows a fridge with its main components and the complete refrigeration cycle. Clicking on the highlighted coloured objects displays information about the respective component.
Embed this animation in your website or learning platform
Copy the code and paste it into your website or learning platform (e.g. Moodle, ILIAS – in HTML mode). The animation stays up to date automatically, and the link leads back to this page.
<div style="position:relative;width:100%;aspect-ratio:16/9"><iframe src="https://www.educational-animation.org/web-animations/refrigerator/en/refrigerator.html" title="Interactive animation: Structure of a refrigerator" style="position:absolute;inset:0;width:100%;height:100%;border:0" allowfullscreen loading="lazy"></iframe></div>
<p><a href="https://www.educational-animation.org/en/structure-of-a-refrigerator/">Structure of a refrigerator – educational-animation.org</a> · MIT licence</p>
Links
Have you corrected an error in the animation or made an improvement? Send us your animation via our contact form.
Description
The 3D model represents a typical household fridge. It shows the external parts (housing, door), the interior fittings and all components of the refrigeration cycle (compressor, condenser, filter drier, capillary tube, evaporator). The model can be freely rotated, zoomed and panned.
Clicking on the coloured objects displays a description of the respective component. The housing and door can be hidden using checkboxes to reveal the components inside. This makes it possible to follow the path of the refrigerant from the compressor via the condenser, the filter drier and the capillary tube to the evaporator and back again.
Components of the Fridge
The table shows the components and their function.
| Component | Description |
| Housing | Sturdy outer shell with thermal insulation, usually made of rigid polyurethane foam. Reduces the amount of heat entering from the surroundings. |
| Door | Closes off the interior. A magnetic seal running all the way round prevents warm room air from getting in. |
| Interior fittings | Shelves, drawers and door compartments for well-organised storage. Some areas have different temperatures. |
| Lighting | Mostly energy-efficient LEDs. Switched on and off automatically by a door contact or sensor. |
| Temperature control | Compares the measured interior temperature with the target temperature and switches the cooling on or off as required. |
| Compressor | Compresses the gaseous refrigerant, raising its pressure and temperature. Central driving component of the refrigeration cycle. |
| Compressor electrics | Starting device, overload protector or electronic motor control. Powers and protects the compressor motor. |
| Condenser | Transfers the heat of the hot refrigerant to the surrounding air. The refrigerant becomes liquid in the process. |
| Filter drier | Removes moisture and dirt particles from the refrigerant. Prevents the capillary tube from freezing up. |
| Capillary tube | Thin, long tube acting as a restriction. Causes the drop in pressure between the condenser and the evaporator. |
| Evaporator | The cold refrigerant absorbs heat from the interior and evaporates. This is where the actual cooling takes place. |
| Defrost water drain | Leads meltwater via a channel and hose into a collecting tray, where it evaporates with the help of the compressor’s waste heat. |
Interactive Controls
The 3D model can be controlled with the following inputs:
- Rotate: Hold down the left mouse button and drag
- Zoom: Turn the mouse wheel or use a two-finger gesture on the touchscreen
- Pan: Hold down the right mouse button and drag
- Select object: Click on a coloured object to display its description
- Show/hide housing and door: Use the “Show housing” and “Show door” checkboxes at the bottom right
Technical Background
A fridge works on the principle of the vapour-compression refrigerator. It transfers heat from the cold interior to the warmer surroundings. Since heat only flows by itself from a warmer to a colder body, work has to be done to achieve this. This work is supplied by the electrically driven compressor.
The refrigeration cycle consists of four steps: In the compressor, the gaseous refrigerant is compressed and heated. In the condenser, it gives off its heat to the surroundings and condenses. In the capillary tube, the pressure is reduced, causing the refrigerant to cool down considerably. Finally, in the evaporator, it absorbs heat from the interior and evaporates. The cycle then starts again.
The key point is that the boiling temperature of the refrigerant depends on the pressure. At the low pressure in the evaporator, it boils at temperatures well below 0 °C. At the high pressure in the condenser, it condenses above room temperature. Modern household fridges mostly use the natural refrigerant isobutane (R600a).
Physical Background
The heat the fridge removes from inside is given off again at the condenser, together with the energy that drives the compressor – which is why the back feels warm (on newer models, often the side walls). How much electricity it needs for this depends mainly on the temperature difference between inside and outside.
Why a Spot Next to the Cooker Costs Electricity
The efficiency of a fridge is described by the coefficient of performance (COP). It indicates how much heat is removed from the interior per unit of electrical power consumed:
\[ \varepsilon_\mathrm{R} = \frac{\dot{Q}_\mathrm{c}}{P_\mathrm{el}} \]
- \( \varepsilon_\mathrm{R} \) – coefficient of performance of the refrigerator
- \( \dot{Q}_\mathrm{c} \) – heat flow removed from the interior (W)
- \( P_\mathrm{el} \) – electrical power consumption of the compressor (W)
The theoretical maximum coefficient of performance results from the Carnot cycle and depends only on the absolute temperatures of the cold and the warm side:
\[ \varepsilon_\mathrm{C} = \frac{T_\mathrm{c}}{T_\mathrm{h}-T_\mathrm{c}} \]
- \( T_\mathrm{c} \) – temperature in the evaporator (K)
- \( T_\mathrm{h} \) – temperature in the condenser (K)
With an evaporation temperature of −20 °C (253 K) and a condensation temperature of 40 °C (313 K), the Carnot coefficient of performance is about 4.2. Real fridges achieve considerably lower values due to losses. The smaller the temperature difference between the interior and the surroundings, the more efficiently the fridge operates. For this reason, it should not be placed next to heat sources such as a cooker or radiator.
Notes on the Model
The 3D model is a simplified, schematic representation. A real fridge includes further components such as pipe connections, fans (in no-frost appliances), defrost heaters, door hinges, feet and wiring. The position and design of the condenser and evaporator vary depending on the manufacturer and type of appliance.
Use in the Classroom
Tasks
Tasks that can be worked through with the animation:
- Hide the housing and the door (“Show housing”, “Show door”). Follow the path of the refrigerant from the compressor back to the compressor and name the components in the right order.
- Click on the condenser and the evaporator. Where does the refrigerant give off heat, where does it take up heat – and is it a gas or a liquid there?
- Click on the capillary tube. Why does the refrigerant cool down strongly after it, although nothing cools it from outside?
- Click on the defrost water drain. Where does the water come from, where is it led – and how does the compressor help it to evaporate?
Worksheets
Worksheet “The Refrigeration Cycle in a Fridge” with answers: Word (editable) · PDF
Related Animations
Overview
| Title | Fridge |
| Target group | Teachers and presenters |
| Features | Full-screen mode Lossless zoom Supports large screens and projection screens |
| Licence | Animation (code): MIT · Text and graphics: CC BY 4.0 |
Sources and Origin
- H. D. Baehr, S. Kabelac: Thermodynamik – Grundlagen und technische Anwendungen. Springer Vieweg, Berlin.
- NIST Chemistry WebBook: thermophysical properties of isobutane (R600a) – boiling pressures in the worksheet.
Parts of the program code for this animation were created with the help of AI tools. The idea, design and technical responsibility remain with us.
Cite this post
The animation (code) is published under the MIT licence, text and graphics under CC BY 4.0: you may use, share and modify everything freely – please give credit. The easiest way is to copy this citation:
Sebastian Rikowski: Structure of a refrigerator. educational-animation.org, 2026. https://www.educational-animation.org/en/structure-of-a-refrigerator/ – Licence: code MIT, text and graphics CC BY 4.0.
If you use the animation, we would greatly appreciate a link to our site or a brief mention of it. It helps others find us – and helps us keep going.